Solar Power System
|
 
|
|
Off-grid Solar Power System
with 3-day Reserve Power
Series: SPS3-12-24VDC
Features
    
3-day Minimum System Reserve Power
    
Provides Regulated 12/24 Vdc Output
    
Weatherproof Vented Enclosure
    
Preassembled, Prewired, Ready-To-Install
    
Deep-cycle Maintenance Free Battery
    
Applications
|
- Wireless Sensors
- Radio Transmitters, Receivers
- Process Controls, Instrumentation
- LED Lighting
- Oil & Gas Instrumentation
- SCADA & Telemetry
|
- Pond Aeration Systems
- Security Systems
- Surveillance Equipment
- Irrigation System
- Pool & Spa Controls
- Water Pumping, Valves
|
Description
Models include a weatherproof, vented fiberglass or metal enclosure with a gasketed hinged door. Each model includes all the required
system components to get you up and running right out of the box. Just
mount and connect the included solar panel, Install and connect your equipment,
flip the internal circuit breaker and you done.
|
How to Select the Correct Solar Power System for Your Application
|
1. Identify the zone your system will be installed from the map on the right.
2. Use the formula below to determine the
amp hours per day your equipment requires.
This is done by multiplying the operating
current by the number of hours per day your
equipment will be required to operate.
3. Based on the zone the solar power system
will be installed and the amp hour per day
requirement, use the chart below to identify
a corresponding "Output Capacity" letter.
4. Use the model number charts below to
locate the correct "Output Capacity" letter
and select your model number.
Note, this system provides both 12 vdc and 24 vdc. You must combine both your 12 Vdc Load-amp Hrs/day, and your 24 vdc Load-amp Hrs/day to estimate your total Load-amp Hrs/day.
Example:
(Equipment Current Draw in Amps +10%) X (Equipment Run Time in Hours = Load-amp Hrs/day
(12Vdc Load) 0.10 + 0.010 = 0.110 Amps x 24 hrs = 2.64 Load-amp Hrs/day
(24Vdc Load) 0.04 + 0.004 = 0.044 Amps x 2 = 0.88 x 24 hrs = 2.11 Load-amp Hrs/day
2.64 Load-amp Hrs/day + 2.11 Load-amp Hrs/day = 4.75 Total Load-amp Hrs/day
Based on this example you would pick:
Letter "D10" for Zone 5, "F10" for Zones 3 or 4, "G10" for Zone 2, and "I10" for Zone 1.
|
Load-amp Hrs/day
|
1
|
1.5
|
2
|
2.5
|
3.5
|
5
|
6
|
7.5
|
8.5
|
10
|
12
|
15
|
17
|
Zone 1
|
C2
|
E3
|
F4
|
G5
|
H7
|
I10
|
J12
|
K15
|
L17
|
-
|
-
|
-
|
-
|
Zone 2
|
B2
|
C3
|
D4
|
E5
|
F7
|
G10
|
H12
|
I15
|
I17
|
J20
|
K25
|
L30
|
-
|
Zone 3
|
B2
|
B3
|
C4
|
D5
|
E7
|
F10
|
G12
|
H15
|
H17
|
I20
|
J25
|
K30
|
L35
|
Zone 4
|
A2
|
B3
|
C4
|
C5
|
D7
|
F10
|
F12
|
G15
|
H17
|
H20
|
I25
|
J30
|
K35
|
Zone 5
|
A2
|
B3
|
B4
|
C5
|
D7
|
D10
|
F12
|
F15
|
G17
|
G20
|
H25
|
I30
|
J35
|
|
General Specifications
|
Operating Temperature:
|
-40 to 140 ºF (-40 to 60 ºC)
|
Enclosure (-26, -35, -55 models):
|
Fiberglass/Plastic Blend NEMA 4X
|
Enclosure (-75, -100, -110 models):
|
Aluminum, Rainproof
|
Minimum Battery Reserve Time:
|
3 days (72 hrs)
|
Regulated Output:
|
12/24 Vdc
|
Installation:
|
Side of Pole, Roof or Wall Mounted
|
Estimated Battery Life:
|
4+ Years*
|
|
Available Models
|
Model Number
|
SPS3-12-24VDC-10W-26
|
SPS3-12-24VDC-20W-35
|
SPS3-12V-24DC-30W-55
|
Output Capacity (Letter Code)
|
A2
|
B2, B3, B4
|
C2, C3, C4, C5
|
Solar Panel Watts
|
10 Watt, 18V
|
20 Watt, 18V
|
30 Watt, 18V
|
Charge Controller
|
6 A
|
6 A
|
6 A
|
Battery Capacity
|
12V, 26 Ah
|
12V, 35 Ah
|
12V, 55 Ah
|
Enclosure Size inch (mm)
|
12 X 8 x 6.4"
(304 x 203 x 162mm)
|
12 X 8 x 6.4"
(304 x 203 x 162mm)
|
13.8 x 11.9 x 6.8"
(351 x 302 x 173 mm)
|
|
|
Model Number
|
SPS3-12-24VDC-40W-55
|
SPS3-12-24VDC-50W-75
|
SPS3-12-24VDC-60W-75
|
Output Capacity (Letter Code)
|
D4, D5, D7, D10
|
E5, E7
|
F7, F10, F12, F15
|
Solar Panel Watts
|
40 Watt, 18V
|
50 Watt, 18V
|
60 Watt, 18V
|
Charge Controller
|
6 A
|
6 A
|
6 A
|
Battery Capacity
|
12V, 55 Ah
|
12V, 75 Ah
|
12V, 75 Ah
|
Enclosure Size inch (mm)
|
13.8 x 11.9 x 6.8"
(351 x 302 x 173 mm)
|
16 x 16 x 10"
(406 x 406 x 254 mm)
|
16 x 16 x 10"
(406 x 406 x 254 mm)
|
|
|
Model Number
|
SPS3-12-24VDC-80W-75
|
SPS3-12-24VDC-120W-110
|
SPS3-12-24VDC-140W-110
|
Output Capacity (Letter Code)
|
G10, G12, G15, G17, G20
|
H12, H15, H17, H20, H25
|
I10, I12, I15, I20, I25, I30
|
Solar Panel Capacity
|
80 Watt, 18V
|
120 Watt, 18V
|
140 Watt, 18V
|
Charge Controller
|
10 A
|
10 A
|
10 A
|
Battery Capacity
|
12V, 75 Ah
|
12V, 55 Ah(x2)
|
12V, 55 Ah(x2)
|
Enclosure Size inch (mm)
|
16 x 16 x 10"
(406 x 406 x 254 mm)
|
18 x 18 x 18"
(457 x 457 x 457)
|
18 x 18 x 18"
(457 x 457 x 457)
|
|
|
Model Number
|
SPS3-12-24VDC-180W-110
|
SPS3-12-24VDC-240W-200
|
SPS3-12-24VDC-280W-200
|
Output Capacity (Letter Code)
|
J17, J25, J30, J35
|
K20, K30, K35
|
L17, L25, L35
|
Solar Panel Capacity
|
180 Watt, 18V
|
240 Watt, 18V
|
280 Watt, 18V
|
Charge Controller
|
20 A
|
20 A
|
20 A
|
Battery Capacity
|
12V, 55 Ah(x2)
|
12V, 100 Ah(x2)
|
12V, 100 Ah(x2)
|
Enclosure Size inch (mm)
|
18 x 18 x 18"
(457 x 457 x 457)
|
18 x 18 x 18"
(457 x 457 x 457)
|
18 x 18 x 18"
(457 x 457 x 457)
|
|
 * Battery life is dependent on system load, depth of charge cycle and ambient temperature.
|
  off grid solar power system, solar power supply, pole mounted solar panel, remote power
  off grid solar power system for SCADA & Telemetry, solar powered, solar generator
|
|
|